Iso15.ResetToReady
This command puts a label into ready-state, according to the VICC state transition diagram from the ISO 15693-3 specification.
This command is an optional command.
Properties
- Command code: 0x2108
- Command timeout: 100 ms
- Possible status codes: General status codes, Iso15.ErrParamNotSupported, Iso15.ErrCom, Iso15.ErrNoTag, Iso15.ErrCollision, Iso15.ErrHf, Iso15.ErrLabel, Iso15.ErrMem
Parameters (request frame)
None
Returned values (response frame)
Name | Type/Size | Description |
---|---|---|
LabelStat | Integer (8 bits) | Status code returned from label. The following Bytes will only be returned, if LabelStat is OK. |